TERMISTAT-6-AL-010-LCD microclimate controller
Description
TERMISTAT-6-AL-010-LCD microclimate controller + TEMPERATURE SENSOR
TERMISTAT-6-AL-010 microclimate controller that controls the operation of fans or heaters depending on temperature and time (ventilation function). It has one electronic control output with smooth power control (first section). The controller also has two 0..10 V signal outputs: the first one is used to control external devices working as the first section, the second one - to control the operation of tilt windows (air inlets).
Properties:
large, easy to read LCD display with spoken messages in Polish.
temperature measurement with digital sensors, possibility of connecting up to 4 TEMP-201 sensors, one sensor included,
built-in one "smooth" control output that allows multi-stage (100 points) speed regulation of single-phase fans or electric infrared heaters with a current strength not exceeding 6 A,
alarm relay output (NO, NC and COM contacts), 24 V, 200 mA,
two 0..10 V signal outputs for connecting external devices (expansion modules, inverters) with the possibility of setting the inverse operation (0% = 10 V, 100% = 0 V). The first is used to control external devices operating as the first section (e.g. liquid section power extension modules, inverters), the second - to control the operation of tilt windows (air inlets).
Functions:
selection of the output operation mode (ventilation / heating),
change of the section operating point and thermal alarms with one parameter: set temperature,
determining the minimum and maximum control of the fluid section,
"Forbidden range" - elimination of a part of the control range of the energy-consuming fluid section and unfavorable for fans,
ventilation: settings of ventilation cycles and levels,
ventilation band (shortening the ventilation time, along with lowering the temperature in the facility below the set value),
alarm function, incl. from exceeding the temperature thresholds (temperature too low, too high), stopping the regulation process, power failure, damage to the temperature measurement path,
differentiation of the operating characteristics of the inlets in relation to the liquid section in order to create negative pressure,
possibility to declare an external temperature sensor (e.g. to correct the alarm threshold, temperature too high).
Technical data:
Supply voltage 230 V, 50 Hz
Electric shock protection class I
First section regulation type - phase
The largest continuous load current of the first section 6 A
Minimum load current of the first section 150 mA (approx. 35 W)
Fuse in the power circuit NONE - requires an external overcurrent switch type "S" B-6 (characteristic type B, In = 6 A)
Alarm relay output Umax: 24 V DC, Imax: 200 mA, Rin: 8.2 Ω
Extension module control type Analog voltage 0..10 V
Output load current 0..10 V Imax: 10 mA for each of the outputs
Temperature setting and measurement range –5 ÷ +50 ° C, with a resolution of 0.1 ° C
Temperature measurement range 40 ÷ +70 ° C, with a resolution of 0.1 ° C
Temperature range of the TEMP-201 sensor operation –25 ÷ +70 ° C
Ambient temperature of the regulator during operation 0 ÷ 40 ° C
Ambient relative humidity 10 ÷ 90% (without steam condensation)
The degree of tightness of the housing is IP55
Housing dimensions (height x width x thickness, including conduits and heat sink) 220 x 202 x 93 mm
Device weight (without the temperature sensor) 1.2 kg
Type of cooperating temperature sensor TEMP-201